SPAL 537 cfm Double Blower 006-A46-22 (12v / 3 speeds)
Part No. 30000154
SPAL TYPE:006-A46-22 GR RA3VCV
- 12v
- Double Blower Wheel
- 537 CFM
- 17.2A current draw
- 3 Speeds (Aluminium resistor supplied)
- Includes Grid
- Fits many Fendt and Massey Ferguson machines that use MF and Fendt Parts 3478331M91, 3900468M91, 3900638M91 or LA322794912
- Jumper between electric motor and resistor (NO WIRE HARNESS SUPPLIED)
Fits many Fendt and Massey Ferguson machines that use MF and Fendt Parts 3478331M91, 3900468M91, 3900638M91 or LA322794912
- View Product Details / Technical Specifications
- No application data available / applicable
- View Related Items
Weight:
3.012kg
Shipping costs are not available for this item
Part / Product Specification and Notes
Maximum Airflow (at zero Static Pressure) |
537CFM (910m³/h) |
Standard Features |
Long life |
|
36 Months Guarantee |
Operating Voltage |
12v (tested at:13v) |
IP Rating |
IP30 |
SPAL Type/Description |
006-A46-22 GR RA3VCV |
|
GR: Grid |
|
RA: Aluminium resistor |
|
3V: 3 speeds |
|
CV: Jumper between electric motor and resistor (without wire harness) |
Mounting Bolt/Screw |
M4 screw |
Mounting Torque |
3(+1/-0) Nm |
Certifications |
UNI EN ISO 9001:2008 |
|
ISO TS 16949 |
|
ISO 14001 |
For additional technical details / dimensions please refer to catalogue pages
Technical Drawing
Wiring Guide for 3 Speed Resistors
A 3 speed resistor pack is included with this blower allowing it to be operated at low, medium and high speed settings. Please ensure the fan switch can handle the current draw at maximum power. For 3 speeds you will need a 4 position switch (low, medium, high, off) using wire size of at least 2.5mm²
3 Speed Resistor Wiring Diagram
|
SPAL 3 Speed Resistor Contacts
- Contact MOTOR should be connected to the +ve terminal on the blower motor with the other terminal on the motor leading to GROUND
- Contact 3+ on the resistor should be connected to the HIGH setting on the swtich (+ve supply)
- Contact 2+ on the resistor should be connected to the MEDIUM setting on the swtich (+ve supply)
- Contact 1+ on the resistor should be connected to the LOW setting on the swtich (+ve supply)
|
Performance Table
Centrifugal Blowers 12v - 24v DC |
12v Double Blowers
|
Products described as suitable for original manufacturers on this site are SPAL branded replacement parts and are not manufactured by the Original Equipment Manufacturer (OEM). Original Manufacturer’s names, part numbers and descriptions are quoted for reference purposes only and are not intended to indicate or suggest that our replacement parts are made by the OEM. All SPAL products sold on this website are genuine SPAL Automotive products manufactured in Italy.